Service

The 8964MON modules make extensive use of surface-mount technology
and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field unless directed otherwise by Customer Service.

If your module is not operating correctly, proceed as follows:

Check frame and module power and signal present LEDs.

Verify power at the voltage testpoints (see

Figure 18

) and check fuse if

no voltage is detected.

Check for presence and quality of input signals.

Verify that source equipment is operating correctly.

Check cable connections.

Check output connections for correct I/O mapping (correct input con-
nector is used for the corresponding channel output).

Refer to

Figure 18

for the location of PWR LED and

Table 2 on page 12

for

proper LED indications.

If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.

Refer to the

Contacting Grass Valley

at the front of this document for the

Grass Valley Customer Service Information number.

Figure 18. 8964MON Fuse and Voltage Testpoint Locations

8367_02

Voltage Testpoints

PWR LED

J1

+5V

–5V

+3.3V

+1.5V

Fuse: 2 A 125 V

F1