8981FS Instruction Manual

9

Configuration

Configuration

This section describes:

■

Onboard configuration hardware (switches and LEDs),

■

Module operation modes and appropriate setups,

■

Using the onboard switches to make configuration settings, and

■

Remote configuration and monitoring using the 8900NET interface.

Configuration Switches and LEDs

The 8981FS module can be configured locally using the onboard rotary and
toggle switches shown in

Figure 5

. Two LEDs are used to indicate status of

the configuration process. These four components perform the following:

■

Function (rotary) switch – addresses a desired function for configura-
tion and provides two sets (banks) of 16 functions (0 through 9, A
through F), although not all positions are used.

Note

The Function switch should be kept in position 0 or F when not in use to avoid
any inadvertent change in configuration. 0 and F are inactive positions.

■

2nd FUNC (second function) LED – when on, indicates that the rotary
switch is addressing the second bank (Bank 2) of functions (see

Table 3

on page 15

).

■

SW1 (toggle) switch – actuates or selects the desired setting for the
selected function when the switch is pushed momentarily in either the
Up or Down position.

■

CONF (configuring) LED – when on, indicates the module is initial-
izing or processing configuration information.

Note

Function switch position E (Restore) in Bank 2 can be used to return the
module configuration to the factory default (as shown in

Table 3 on page 15

).

Configuration can also be performed using the 8900NET with GUI. Remote
control can, however, be locked out using the jumper (J5) shown in

Table 5

on page 10

.