26

1. Mains socket and fuses

Connection to mains cable

According to equipment serial number, the power
supplies equipping the Base Station are:
Bivoltage (fitted with an automatic switching system: 100
to 125 V AC and 200 to 240 V AC 50 or 60 Hz). In this
case, no adaptations are required in terms of mains
voltage.
Or monovoltage 100 to 125V AC or 200 to 240V AC 50 or
60 Hz.
Before connecting the Base Station to the mains, to make
sure of the equipement operation voltage. This voltage is
indicated on the label located on the Base Station rear
panel.

FUSE CHANGING
The fuse is located in the mains connector on the back of
the Base Station.
Disconnect the mains plug for access to fuse.
This connector also contains a spare fuse.

2. «MIC OUT» receptacle

Audio output from ambient microphone connected to
camera.
The nominal output level is 0 dB. To modify this level,
refer to the «INSTALLATION» Chapter 10.

N

1

3

2

2 fuses:

- Equipment protection fuse
- Spare fuse.
Fuse type:
110V or 220V: Value T 6,3 AH
250V
P/N: T9000671

1 : Neutral
2 : Ground (connected to chassis ground)
3 : Phase

MIC OUTPUT

2

3

1

Male receptacle

Type: XLR-3-32
P/N: 91.355.161

Corresponding
socket

Type: XLR-3-11C
P/N: 91.355.160

1 : GND
2 : MIC X OUT