Dimensions

Width: 10.8 inches (275 mm)
Depth: 16.5 inches (419 mm)
Height: 3.4 inches (86 mm)

Weight

Approx. 6.8 lb (3.0 kg)

Electrical

Input voltage

AC 100 to 120 V

range

Rated frequency

50 to 60 Hz

Rated input

0.5 A

current

Power

17 W (operating mode),

consumption

15 W (standby mode, 5.5 W sleep mode)

Note: Check the label on the back of the scanner for voltage

information.

Environmental

Temperature

Operation: 41 to 95 °F (5 to 35 °C)
Storage: –13 to 140 °F (–25 to 60 °C)

Humidity

Operation: 10% to 80%

(without

Storage: 10% to 85%

condensation)

Operating

Ordinary office or home conditions; avoid

conditions

extreme dust, direct sunlight, and strong
light sources.

Approvals

Safety UL

1950

CSA C22.2 950

EMC

FCC part 15 subpart B class B
CSA C108.8 class B

USB Interface

Interface type

Universal Serial Bus Specification
Revision 2.0

Electrical

Full Speed mode: 12 Mbit/s,
Hi-speed mode: 480 Mbit/s,
Universal standard Serial Bus Specification
Revision 2.0

Connector type

One receptacle (Type B)

Option Interface Connector

Output voltage

15.2 V; 50 to 60 Hz

Initialization Methods

The scanner can be initialized (returned to a fixed set of
conditions) in the following ways:

AC Adapter Specifications

Rated input

AC 100 to 120 V, 50 to 60 Hz

Rated output

DC 15.2 V, 1.2 A

Temperature

Operation: 41 to 95 °F (5 to 35 °C)

Safety

UL 1950 or UL60950
CSA C22.2

EMC

FCC part 15 subpart B class B
CSA C108.8 class B

Film Adapter Specifications

Electrical

Supplied voltage: DC 15.2V
Rated current: 0.3 A

Transparencies size 35-mm film strip 3 frames

35-mm slide, 2 frames

Readable area

1.9

×

4.9 inches (49

×

125 mm)

Unlocking the Scanner

Be sure to unlock the scanner before using it. Slide the
transportation lock to the unlock position:

If you need to transport the scanner, see page 6.

Hardware
initialization

The scanner is plugged in.

The USB cable is unplugged from the USB port on
the scanner.

Software
initialization

Software sends the ESC @ (initialize the scanner)
command.

The scanner receives a Bus Reset from the USB
interface.

Locked