Optional Components
Camera Joystick Override
A user fabricated cable, external switch, and a 15-pin D connector are
required to implement camera joystick override. Use shielded cable
and connect the shield to the metal connector shell when fabricating the
joystick override cable. Refer to
Figure 30. KAL-32AUX Joystick Override Connector Cable Wiring
LAN
The 32-Crosspoint Remote Aux panels communicate through the
Zodiak Menu (Facility) LAN. Refer to
for information on system topography.
Common
0
619_04_62_r3
1
2
3
4
6
7
8
5
9
10
11
12
13
15
14
Pin 1
Pin 15
Pin 9
D-15 Male
Joystick Override
Connector
(wiring side)
Pin 8
Momentary Contact Switches