3
Carburetor Jetting
1999 XLT Touring, XLT Classic
Engine Model: EC58PL131
AMBIENT
TEMPERATURE
Below -20°F
Below -29°C
-20°F to
+10°
-29°C to
-12°C
+10°F - +40°F
-12°C - +5°C
Above +40°F
Above +5°C
0-900
(0-3000)
250
250
230
210
Altitude
900-1800
(3000-6000)
230
220
210
195
Meters
(Feet
)
1800-2700
(6000-9000)
210
200
190
180
)
2700-3700
(9000-12000)
190
180
175
165
- Shaded zone should drop Jet Needle one position (raise E-Clip)
- Production Setting
PN 9914856 Rev 02 6/98