77

MAINTENANCE

Spark Arrester

Failure to heed the following warnings while servicing the spark arrester could result in serious injury or
death.

• Do not perform service on the spark arrester while the system is hot. Exhaust system temperatures

can reach 1000° F. Allow components to cool sufficiently before proceeding.

• Remove any combustible materials from the area.
• Wear eye protection and gloves.
• Do not stand behind or in front of the vehicle while purging.
• Never run the engine in an enclosed area. Exhaust contains poisonous carbon monoxide gas that

can cause loss of consciousness or death in a very short time.

• Never operate without the spark arrestor.
• Never go under the vehicle while it's inclined.

Use the following procedure to periodically purge accumulated carbon from the exhaust
pipe.

1. Remove the arrester clean-out plugs located on the

bottom of the muffler.

2. Place the transmission in neutral.

3. Engage the park brake.

4. Start the engine.

5. Purge accumulated carbon from the system by

momentarily revving the engine several times.

6. If carbon is expelled, cover or plug the exhaust outlet

and rap on the pipe around the clean-out plugs while
revving the engine several more times.

7. If particles are still suspected to be in the muffler,

elevate the rear of the vehicle one foot higher than the front. Block the wheels.

8. Repeat steps 5 and 6 until no more particles are expelled when the engine is revved.

9. Stop the engine. Allow the arrester to cool.

10. Reinstall the arrester plugs and remove the outlet cover or plug.

WARNING

Clean-Out

Plugs

Exhaust

Outlet