Output Format of the Compensation-Value Table
A separate compensation-value table is prepared and transmitted for each axis to be corrected.
Line: Start
Each compensation-value output begins with the start character < * > ( HEX: 0x2A)
* <CR> <LF>
3 characters
Line: Counter model designation
Output of model designation and unit of measure
N D - 2 3 1 B M M <CR> <LF>
13 characters 5 characters 2 characters
Model display unit, left-aligned Unit of meas. End of line
Line: Axis to be corrected
Output of axis to be corrected
A X I S X 1 = 0 <CR> <LF>
13 characters 3 char. 6 characters 2 characters
Axis to be corrected Separator Axis value End of line
left-aligned
block right-aligned
Line: Axis to be corrected
Output of axis to be corrected
X 1 F C T . X 1 = 0 <CR> <LF>
13 characters 3 char. 6 characters 2 characters
Axis causing the error Separator Axis value End of line
left-aligned block right-aligned
Output Format of the Compensation-Value Table