Remote Operation over the RS-232-C/V.24 Data Interface

Remote Operation over the RS-232-C/V.24 Interface

You can operate the display unit remotely over the RS-232-C/
V.24 data interface. The following commands are available on
the ND 221 B:
Format:
<ESC>TXXXX<CR> Pressed key
<ESC>AXXXX<CR> Output of screen contents
<ESC>FXXXX<CR> Execute function
<ESC>SXXXX<CR> Special function

Sequence of commands

Meaning

<ESC>T0000<CR>

"0" key

<ESC>T0001<CR>

"1" key

<ESC>T0002<CR>

"2" key

<ESC>T0003<CR>

"3" key

<ESC>T0004<CR>

"4" key

<ESC>T0005<CR>

"5" key

<ESC>T0006<CR>

"6" key

<ESC>T0007<CR>

"7" key

<ESC>T0008<CR>

"8" key

<ESC>T0009<CR>

"9" key

<ESC>T0100<CR>

"CL" key

<ESC>T0101<CR>

"-" key

<ESC>T0102<CR>

"." key

<ESC>T0104<CR>

"ENT" key

<ESC>T0105<CR>

"MOD" key

<ESC>T0107<CR>

"1/2" (datum) key

Sequence of commands

Meaning

<ESC>T1000<CR>

"CE+0" keys

<ESC>T1001<CR>

"CE+1" keys

<ESC>T1002<CR>

"CE+2" keys

<ESC>T1003<CR>

"CE+3" keys

<ESC>T1004<CR>

"CE+4" keys

<ESC>T1005<CR>

"CE+5" keys

<ESC>T1006<CR>

"CE+6" keys

<ESC>T1007<CR>

"CE+7" keys

<ESC>T1008<CR>

"CE+8" keys

<ESC>T1009<CR>

"CE+9" keys

<ESC>A0000<CR>

Output of model designation

<ESC>A0100<CR>

Output of 14-segment display

<ESC>A0200<CR>

Output of current value

<ESC>A0301<CR>

Output of error text

<ESC>A0400<CR>

Output of software number

<ESC>A0900<CR>

Output of highlighted fields

<ESC>F0002<CR>

Print

<ESC>S0000<CR>

Counter RESET

<ESC>S0001<CR>

Lock keyboard

<ESC>S0002<CR>

Release keyboard