3 touch probe table, General information, Editing touch probe tables – HEIDENHAIN TNC 320 (34055x-06) Cycle programming User Manual
Page 260: Touch probe table, Using touch probe cycles 13.3 touch probe table

Using Touch Probe Cycles
13.3 Touch probe table
13
260
TNC 320 | User's Manual Cycle Programming | 5/2013
13.3
Touch probe table
General information
Various data is stored in the touch probe table that defines the
probe behavior during the probing process. If you run several touch
probes on your machine tool, you can save separate data for each
touch probe.
Editing touch probe tables
To edit the touch probe table, proceed as follows:
Select the Manual Operation mode.
Select the touch probe functions by pressing
the TOUCH PROBE soft key. The TNC displays
additional soft keys: see table above
Select the touch probe table: Press the TCH
PROBE TABLE soft key
Set the EDIT soft key to ON
Using the arrow keys, select the desired setting.
Perform desired changes.
Exit the touch probe table: Press the END soft key