Rs-422/v.11 interface, Ethernet interface rj45 socket – HEIDENHAIN iTNC 530 (340 49x-05) ISO programming User Manual
Page 571

HEIDENHAIN iTNC 530
571
1
8
.2 Pin La
y
outs and Connecting Cables f
o
r the D
a
ta Int
e
rf
aces
RS-422/V.11 interface
Only non-HEIDENHAIN devices are connected to the RS-422
interface.
Ethernet interface RJ45 socket
Maximum cable length:
Unshielded: 100 m
Shielded: 400 m
The interface complies with the requirements of
EN 50 178 for “low voltage electrical separation.”
The pin layouts on the TNC logic unit (X28) and on the
adapter block are identical.
TNC
Connecting cable 355 484-xx
Adapter block
363 987-01
Female
Assignment
Male
Color
Female
Male
Female
1
RTS
1
Red
1
1
1
2
DTR
2
Yellow
2
2
2
3
RXD
3
White
3
3
3
4
TXD
4
Brown
4
4
4
5
Signal GND
5
Black
5
5
5
6
CTS
6
Violet
6
6
6
7
DSR
7
Grey
7
7
7
8
RXD
8
White/Green
8
8
8
9
TXD
9
Green
9
9
9
Housing
Ext. shield
Housing
Ext. shield
Housing
Housing
Housing
Pin
Signal
Description
1
TX+
Transmit Data
2
TX–
Transmit Data
3
REC+
Receive Data
4
Vacant
5
Vacant
6
REC–
Receive Data
7
Vacant
8
Vacant