Programming: Q parameters
8.8 A
d
ditional functions
Example: Assign the value of the active scaling factor for the
Z axis to Q25
21
-
TT: Break tolerance for length LBREAK
22
-
TT: Break tolerance for radius RBREAK
23
-
PLC value
24
-
Tool type TYPE
0 = milling cutter, 21 = touch probe
27
-
Corresponding line in the touch-probe table
32
-
Point angle
34
-
Lift off
Touch probe cycles, 990
1
-
Approach behavior:
0 = standard behavior
1 = effective radius, set-up clearance is zero
2
-
0 = probe monitoring off
1 = probe monitoring on
4
-
0 = stylus not deflected
1 = stylus deflected
Execution status, 992
10
-
Block scan active
1 = yes, 0 = no
11
-
Search phase
14
-
Number of the last FN14 error
16
-
Real execution active
1 = execution , 2 = simulation
Group name, ID no.
Number
Index
Meaning
55 FN 18: SYSREAD Q25 = ID210 NR4 IDX3