14

Installation

I

NSERT

C

LEARANCES

TO

C

OMBUSTIBLES

(I

NSTALLED

I

N

M

ASONRY

F

IREPLACE

):

The fireplace insert model includes a surround faceplate and a pedestal. When installing this unit, ensure that the

pedestal is removed from the inside of the hopper and installed on the bottom of the unit.

SIDE WALL

8 inches

(20.3 cm) from the body of the heater

FACING ON MASONRY FIREPLACE

8 inches

(20.3 cm) from the body of the heater

MANTLE

8 inches

(20.3 cm) from the body of the heater

F

REESTANDING

C

LEARANCES

TO

C

OMBUSTIBLES

AND

M

INIMUM

A

LCOVE

S

IZE

:

Maintain these clearances to combustibles.

This unit may be installed in an Alcove.

SIDE WALL TO UNIT 6 inches (20.4 cm)

MIN. ALCOVE WIDTH 36 inches ( 91.4 cm)

BACK WALL TO UNIT 3 inches ( 7.6 cm)

MIN. ALCOVE HEIGHT 48 inches (121.9 cm)

ADJACENT WALL

2 inches ( 5.0 cm)

MIN. ALCOVE DEPTH 30 inches ( 76.2 cm)

���

���

���

��

��

��

I

NSERT

D

IMENSIONS

:

WIDTH:

23 3⁄4 inches (60.4 cm)

HEIGHT:

22 7⁄8 inches (64.6 cm)

DEPTH:

23 7⁄8 inches (60.5 cm)

DEPTH FROM FRONT OF UNIT TO SURROUND:

12 7⁄8 inches (32.6 cm)

Advertising