TO AVOID PERSONAL INJURY DO NOT REMOVE OR REPLACE COVER WHEN PELLET STOVE IS HOT!

TOOLS REQUIRED:

11

/

32

” socket or wrench

REMOVAL OF DOOR COVER:

When stove is off and cool, open the door. Remove the four #8 hex nuts

around the inside of the glass retainer shown in Figure 1.

Remove door cover from door by gently sliding the studs out of the holes.

If it is difficult to remove the cover, the glass retainer may be pinching

the threads on the studs. Slightly loosen the four screws (by each of the

studs).

REPLACEMENT OF DOOR COVER:

Slide new door cover into place and hand tighten the four #8 hex nuts

around the inside of the glass retainer. Ensure the four screws are also

hand tight and close door.

CLEANING THE DOOR COVER:

Painted surfaces should be wiped with a damp cloth periodically. It is important to note that fingerprints and other

marks can leave a permanent stain on plated finishes. To avoid this, give the door a quick wipe with denatured

alcohol on a soft cloth BEFORE lighting the stove. Never clean surfaces when hot. Do not use other cleaners or

abrasives as they may leave a residue or scratches, which can become permanently etched into the surface.

28

Inner side of Meridian door.

Installation

P

LATED

D

OOR

I

NSTALLATION

:

quick wipe with denatured alcohol on a soft cloth BEFORE lighting the fireplace. Never clean surfaces when they

are hot. Do not use other cleaners or abrasives as they may leave a residue or scratches, which can become

permanently etched into the surface.

REMOVAL OF LOUVER BAR SET:

Door must be open. The three arrows in figure 3 point to three of the

nuts that hold the louvers on. There are three nuts on each end. Remove

the six nuts by hand; if the nuts are tight, a

11

/

32

” socket can be used.

When removing the louvers, pull one end of the louver up over the stud.

If it is difficult to remove the louver, push on one side from the front, then

pull the other end off the second stud.

REPLACEMENT OF LOUVER BAR SET:

Place one slotted end of new louver over a stud, then slide the other slot

over the corresponding stud; replace the nuts and hand tighten. Close

door when all three louvers are replaced.

CLEANING THE TRIMS:

Painted surfaces should be wiped with a damp cloth periodically. It

is important to note that fingerprints and other marks can leave a

permanent stain on plated finishes. To avoid this, give the surface a

Door with louvers.