Building in, Installation, Building over a cupboard or drawer – Electrolux U26227 User Manual

Page 11: Cut out size, Supply connections

Advertising
background image

1 1

Building In

ON/OFF SWITCH

FLEX
OUTLET

ON/OFF SWITCH

FLEX
OUTLET

FO 0763

FO 0764

1

2

Building over a cupboard or
drawer

If the hob is to be installed above a cupboard or drawer it
will be necessary to fit a heat resistant board below the
base of the hob on the underside of the work surface.
It is also recommended to carry out the electrical
connection to the hob as shown in diagrams 1 and 2.

Rectangular cut-out size for hob

Installation

The hob must be installed according to the
instructions supplied.

The hob must be installed by qualified
personnel
to the relevant British Standards.

Please, ensure that, once the hob is installed,
it is easily accessible for the engineer in the
event of a breakdown.

WHEN THE HOB IS FIRST INSTALLED

Once the hob has been installed, it is important
to remove any protective materials, which were
put on in the factory.

The manufacturer will not accept liability,
should the above instructions or any of the
other safety instructions incorporated in this
book be ignored.

Cut Out Size

The dimensions of the cut-out are given in the diagram.

Supply Connections

This hob is designed to be connected to 230-240 V (50
Hz) electricity supply.

The cable used to connect the hob to the electrical supply
must be 6mm, PVC twin and earth, and fused to 30amp.

It is necessary that you install a double pole switch
between the hob and the electricity supply (mains), with
a minimum gap of 3mm between the switch contacts
and of a type suitable for the required load in compliance
with the current rules.
The switch must not break the yellow and green earth
cable at any point.

550

470

580

500

55 min.

FO 2225

Advertising