Electrical connections, Supply cable specifications – Electrolux U26227 User Manual

Page 13

Advertising
background image

1 3

Electrical connections

The hob should be connected to a double pole switch
with a minimum gap of 3 mm. between the switch
contacts and of a type suitable for the required load in
compliance with the current electric regulations. The
switch should be sited within 2m of the hob and be easily
accessible upon completion of the installation.

The switch must not break the yellow and green earth
cable at any point.

Ensure that the hob supply cord does not
come into contact with surfaces with
temperatures higher than 50 deg. C.

)

Any electrical work required to install this hob
should be carried out by a qualified electrician or
competent person, in accordance with the current
regulations.

THIS HOB MUST BE EARTHED.

The manufacturer declines any liability should these
safety measures not be observed.

This hob is designed to be connected to a 230-240V 50Hz
AC electrical supply.

Before switching on, make sure the electricity supply
voltage is the same as that indicated on the hob rating
plate. The rating plate is located on the bottom of the
hob. A copy is attached on the back cover of this book.

The hob is supplied without supply cord. A 3 core flexible
supply cord must be fitted, in accordance with the
specification given in the relevant tables.

1) Remove the mains terminal cover plate from

the underside of the hob, to expose the mains
terminal block.

2) Loosen the two cable clamp screws and lift

the top section of the clamp enough to allow
the cable to be passed through.

3) Connect the red (live) wire to the terminal which

is marked with the number

1

.

4) Connect the black (neutral) wire to the terminal

which is marked with the number

4

.

5) After fitting a green or yellow/green sleeve over

the bare copper wire (earth wire), connect the
exposed end to the terminal which is marked

with the earth symbol

or with the number

5

.

NOTE:

The earth wire should be about 2 cm. longer
than the live and neutral wires.

6) Secure the cable by means of the clamp

screws and refit the terminal block cover.

Supply Cable Specifications

Connection

Min. size

Cable / flex Fuse

via

Cable/flex

type

• Cooker

6 mm

2

PVC/PVC

30 A

Control

twin and

Circuit

earth

For Uk use only

For Europe use only

Min. size Cable/flex

Cable / flex type

Fuse

2.5 mm

2

H05 RR-F / H05V2V2

30 A

H05 BB-F

FO 0488