3 cabling recommendations, 4 installing the power modul into the inverter, Cabling recommendations – SMA POWER MODUL User Manual

Page 9: Installing the power modul into the inverter

Advertising
background image

SMA Solar Technology AG

Electrical Connection

Installation Guide

PModul-IEN094510

9

4.3 Cabling Recommendations

If you have to replace the cable provided, please observe the following requirements for the new
cable:

• External diameter: minimum 6.5 mm, maximum 8 mm
• Quantity of wires and the cross-sectional area: minimum 2 x 0.5 mm

2

, maximum 2 x 2.5 mm

2

• UV resistant (only necessary for outdoor use)
• The cable from the Power Modul to the consumer may not exceed a length of 10 m.

Preparing the new cable

Prepare the cable as shown in the illustration.

4.4 Installing the Power Modul into the inverter

1. Open the inverter as described in its installation guide.
2. Loosen the screw of the display, until the display can be flipped up. Flip up the display until it

clicks into place.

No installation of the Power Modul possible in event of the use of RS485
communication.
The Power Modul is to be installed on the slot for modules. The slot can only be fitted with
1 module. If the RS485 communication module (DM-485CB-10) is already installed, you
must decide on one module. If you want to install the Power Modul, you must first remove
the RS485 communication module.