background image

Opening and Closing

SMA Solar Technology AG

46

SB12-17-IA-en-52

Installation Guide

4. Unlock all the DC plug connectors: Use a

screwdriver with a width of 3.5 mm.
– Insert a screwdriver into one of the side slits (1).
– Disconnect the DC plug connectors (2).

5. Pull out the AC plug.

DANGER!
Danger to life due to unsafe disconnection from the PV generator!

A secure separation from the PV generator is only guaranteed after pulling off the
Electronic Solar Switch and all DC plug connectors.

• Remove all DC plug connectors to

completely disconnect the PV generator
from the inverter.