CFr S

erieS

P

reSSure

r

eduCing

S

uPPly

r

egulatorS

-2-

I

nstallatIon

c

ontInued

,

9.

Should the Mark CFR regulator be installed

in an existing installation, it may be nec-

essary to install spacers on the mounting bolts

to adapt to the installation. If mounting

bolts are too long place a spacer on

the mounting bolt and ensure at

least two full threads of engagement.

s

tartup

and

a

djustment

1.

Once installation is complete and downstream

equipment is properly adjusted, slowly open the

supply and downstream shutoff

valves (if installed) while using pressure gauges

to monitor supply and outlet pressure.

2.

Should outlet pressure adjustment be required,

install and monitor outlet pressure using

a gauge during the start-up procedure.

The Mark CFR regulator outlet pressure can

be raised or lowered by loosening the locknut

(10), and turning the adjustment screw (3),

clockwise to increase outlet pressure, or counter

clockwise to decrease outlet pressure.

3.

Tighten the locknut (10) one the desired outlet

pressure has been properly set as required.

4.

Periodically inspect the regulator for signs or

wear or damage, and repair or replace

as necessary.

For more information or questions, please contact a

Jordan Valve Representative.

m

ark

cFr a

ssembly