Grounding system, Lightning protector installation – Enterasys Networks 9033348-02 User Manual

Page 38

Advertising
background image

Grounding System

3-4 Antenna Installation

Grounding System

Direct earth grounding of the antenna and the Lightning Protector is necessary to protect
the installation from lightning and the build-up of static electricity.

The grounding system must satisfy the following requirements:

•

The antenna mast, RoamAbout Access Point, and RoamAbout Lightning Protector
must be connected to the same ground.

•

The antenna and the mounting structure require a separate earth ground connection.
Check with a certified antenna installer to make sure the antenna is properly grounded.

•

Ensure that the cable between the antenna and Lightning Protector is at least 0.9 meters
(3 feet) away from high-voltage or high-current cable.

•

A good electrical connection must be made to one or more ground rods, using at least
a 10AWG ground wire and noncorrosive hardware.

•

The grounding system must comply with electrical codes and safety standards that
apply in your locality.

Have a qualified electrician verify that your RoamAbout outdoor installation is properly
grounded.

Lightning Protector Installation

Lightning protection is designed to protect people, property and equipment by providing a
path to the ground whenever lightning strikes your antenna installation. The RoamAbout
Lightning Protector is an indispensable part of such a grounding system to protect your
electronic equipment from transients and/or electrostatic discharges at the antenna.

For optimal protection, the location of the RoamAbout Lightning Protector:

•

Must be as close as possible to the point where the antenna cable enters the building.

•

Allow for easy access to the Lightning Protector so that the Gas Discharge Tube
(GDT) in the Lightning Protector can be replaced as necessary.

•

Provide a connection to the same grounding system as the RoamAbout Access Point
and the antenna mast as described in the

“Verify Component Connector Polarity”

section on page 3-2

.

CAUTION: A properly installed safety grounding system is necessary to
protect your RoamAbout outdoor installation from lightning strikes and
static electricity build-up.

Advertising