Audible recharge signal

Select the function with the touch pad (8), the green indicator appears.

Once recycled an acoustic signal indicates that the compact unit is ready.

Open flash "test"

Having pressed the touch pad to release a flash, the green «READY» light will

appear again once the unit is recharged. If the green light does not appear the

charge system could be defective.

Please contact and send to an authorized Elinchrom service.

5

Test and Ready

Sychronisation socket

The standard socket 3.5 mm mini-jack (6).

N.B. Do not link ELINCHROM units by cable to other manufacturers sync outlets.

ELINCHROM uses the low voltage (5 V) for security reasons.

Sync

8

Beep

All RX units, Style RX, Digital RX, Ranger RX are equipped with the Remote Plug, to connect the

EL-Skyport Trigger and Remote System. With the EL- Skyport RX Trigger Set 19362,

the RX units can be triggered wireless, up to approximately 100 m distance. Apart from triggering,

the Transmitter offers modelling lamp on /off settings and flash power control in 1/10th steps.

By using the EL- Skyport Computer Remote / Trigger Set 19361, all RX functions can be

controlled and operated with a MAC° or Windows° computer.

For details of the most advanced wireless system please visit

www.elinchrom.com

> Products >

RX Multi Remote > EL-Skyport.

19361

19362

Wireless Remote Control and Flash Triggering

Troubleshooting

1. The mains switch (3) is ON ("I" position), but not light up:
• Switch OFF the unit and change the mains fuse (2)

• Use only time-lag fuse (16 AT), corresponding to the Style RX model
2. The switch (3) is lit, the open flash ready is lighting up but does not function.
• The flashtube in the flashhead may be faulty (see page 11)

• If replacing the flashtube does not solve the problem, the cause could be a

component failure => please return the unit to an authorised Elinchrom service.

3. The ON/OFF switch (3) is lit but the open flash signal (6) is not lit
• Temporary break for overheating, caused by fast flash sequences or ventilation

slots obturated

• Fan cooling defective => the unit turns off automatically and cannot be fired any

more. After a break for cooling, the flash is ready again for operation.

• If after several minutes of break for cooling the ready signal (6) is not lit, the cause

could be a component failure. However, high voltage may remain on the capacitor

circuits. => DO NOT ATTEMPT TO REPAIR THE UNIT. In this case please send the unit

to an authorised Elincrom station.