8

23018

23101

23022

230V Modelling lamps and fuses
Unit

Modelling lamp

Code

Socket

Fuse

Code

Style 300RX

250W halostar

23018

E27

2,5AF 19033

Style 600RX

250W halostar

23018

E27

2,5AF 19033

Style 1200RX

300W halogen

23022

GX 6,35

2,5AF 19033

The touch pad (14) controls the modelling lamp on/off and the proportional light.

Select the power with the touch pad (15). The modelling light output (100%) is achieved when

the power value is set to maximum.

Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the

light output is proportional to the selected flash power.

For all types of Style RX compact flash units, use maximum 250 - 300W modelling lamps.

This lamp socket adapter E27 to GX 6.35 (code 23101) allows the use of the halogen lamp

300W, GX 6.35 (code 23022) for Style 300 and 600 RX units.

If the modelling lamp does not light up.

1. The filament is broken after long use (replace lamp and fuse)

2. The filament is broken after shock (replace lamp and fuse)

3. An internal component failure (return the unit to customer service)

Modelling Light

120V Modelling lamps and fuses
Unit

Modelling lamp

Code

Socket

Fuse

Code

Style 300RX

150W halogen

23037

BA15D

4 AF

19035

Style 600RX

150W halogen

23037

BA15D

4 AF

19035

Style 1200RX

250W halogen

23038

BA15D

4 AF

19035

120V «Canada Version» Modelling lamps and fuses
Unit

Modelling lamp

Code

Socket

Fuse

Code

Style 300RX

150W halogen

23012

E27

4 AF

19035

Style 600RX

150W halogen

23012

E27

4 AF

19035

Style 1200RX

150W halogen

23012

E27

4 AF

19035

230V Modelling lamp options:

120V Modelling lamp:

23037

Advertising