Selecting your location

Press CITY- the city display will blink and the
latitude and longitude will be displayed. Press "+"
or "-" to select your location. Press CITY to
confirm your selection. If the abbreviation for you
city does not appear, your location can be set
manually (See "Manually setting your location").
After a short calculation period the weather station
will show the sunrise and sunset times, the moon
phase and neap tide (TIDE LO), medium water
level (TIDE MID) or spring tide (TIDE HI).

Manually setting your location

Press and hold CITY. The cities display shows
"-- -- --". Press "+" or "-" to select the first letters
of your location. Press CITY to confirm your
selection. Set letters 2 and 3 of your location in
the same way.
On the display GMT appears and the time zone
indicator flashes. Set the difference of your time
zone to GMT (Greenwich Mean Time) by pressing
UP and DOWN (For the UK set 0:00).
Press CITY to confirm your selection. Now set the
longitude and latitude of your location in the same
way.

A table with the longitudes and latitudes for some
cities can be found at the end of these operating
instructions.

After a short calculation time the weather station
displays the times for sunrise and sunset and the
moon phase as well as neap tide (TIDE LO),
mean water level (TIDE MID) or spring tide (TIDE
HI).

Outdoor sensor channel selection

Press "CH" on the back side of the weather
station to select channel 1, 2 or 3. If the symbol

appears, the temperature and humidity of the

3 outdoor sensors will alternate on the display.
Press and hold "CH" to restart the outdoor
temperature and humidity reception process.












Additional information for the
outside sensor

Please position your sensor in a covered location
and make sure that the sensor does not get wet
and is not exposed to direct sunlight. To
guarantee optimal radio transmission, position the
station and sensor so that as few obstacles as
possible (walls, metallic components) interfere
with reception.
Sources of electrical interference can also be
detrimental to reception.

Temperature and frost alarms

Setting the temperature alarm
Press "CH" to select the outdoor sensor. Press
and hold "-" to set the alarm temperature. The
outdoor temperature will blink.
Press "+" or "-" to set the maximum value for the
temperature alarm. Confirm your setting by
pressing MODE. Press "+" or "-" to set the
minimum value for the temperature alarm.
Confirm your setting by pressing MODE.

Activating/deactivating the temperature and
frost alarms
The temperature and frost alarms can be
activated or deactivated by repeatedly
pressing "-".

If the frost alarm is activated the

symbol will

appear next to the outdoor temperature. The
alarm will sound at the set temperature.

If the temperature alarm is activated the

symbol will appear next to the outdoor
temperature. The alarm will sound at the set
temperature.
If both frost and temperature alarms are activated
then both symbols will appear.



- 15 -

Disposal

Disposal of the electronic appliance
This electronic appliance may not be
disposed of with normal household waste.
Dispose of the unit at an approved disposal
facility or at your local recycling centre.
Please observe the current rules and
regulations when disposing of the
appliance. Contact the disposal system if in
doubt.


Disposal of the batteries
Please dispose of your batteries properly in
containers especially set up at retailers.
Batteries do not belong in household waste.
Dispose of the batteries at an approved
disposal facility or at your local recycling
centre. Contact the disposal system if in
doubt.

Technical data

Weather station
Operating temperature : 0°C – +55°C
Dimensions: 12,6 x 12,5 x 5,6 cm
Display of the weather station: 8,0 x 8,0 cm
Weight: 299g
Batteries: 3 x 1,5V AA

Sensor
Operating temperature: -20°C – +65°C
Dimensions: 4,9 x 9,6 x 3,3 cm
Weight: 75g
Batteries: 2 x 1,5V AA

Declaration of conformity

If used as intended this product conforms to the
basic standards of § 3 and the other relevant
provisions of the FTEG (Section 3 of the R&TTE
directive).
The declaration of conformity can be requested
here: [email protected]

Warranty

We provide a 3-year warranty for this item. The
warranty period starts from the date of sale
(receipt, proof of purchase). Within this period we
rectify all faults which are attributable to material
and manufacturing defects at no cost. For
damage which is caused by improper treatment,
e.g. dropping, knocking, or water damage, there is
no warranty claim.

Order service

You can add up to 3 outside sensors to your
temperature station. One sensor is included in the
purchase.
Additional outside sensors can be ordered by fax
+49(0)6198-5770-99 or online at www.inter-
quartz.de.
The price for one sensor is EUR 5.00 and for 2
sensors EUR 10.00 including operating
instructions and packaging, excluding VAT and
despatch.