Problem Solving

To Clear Blockages in Hose

NOTE:Turn off the switch and unplug the electrical cord

before clearing hose.

1. Locate upper hose adapter on the back of the cleaner.

2. Remove nested wands from back of cleaner for easy

access to hose adapter tabs.

3. Press hose adapter tabs together and pull hose adapter

away from cleaner. The hose adapter will unscrew off hose
for easy access to debris if necessary.

4. Check for blockages at cleaner opening and in hose. If

no blockage is found, continue to step 5. If blockage is
found, clear and continue to step 11.

Hose
Adapter
Tabs

Nested
Wands

5. Locate lower hose adapter on the back of the cleaner.

6. Remove lower hose adapter from rear of cleaner by lifting

up and twisting.

7. Check for blockages in the hose and base hose. Flexing

the hose may help loosen any blockage. If no blockage
is found, continue to step 8.
If blockage is found, clear
and continue to step 11.

8. Remove hood from cleaner and check for a blockage in

the brush roll area. Make sure the hose inlet is clear.

9. After the blockage is found and cleared, replace the hood

on the cleaner.

10. Place lower hose adapter back into the base hose.

11. Install the upper hose adapter onto the back of the

cleaner, line it up with the cleaner opening and push it
against the cleaner until both tabs lock into place.