Electrolux 29 – Electrolux EKM 70150 User Manual

Page 29

Advertising
background image

electrolux 29

LEVELLING FEET

PENCIL LINE ON THE FLOOR

PLAN VIEW OF THE COOKER

580 mm.

100 mm.

300 mm.

295 mm.

WALL FACE

A

BACK OF COOKER

SIDE VIEW

OF THE COOKER

BASE OF COOKER

ENGAGEMENT EDGE FOR

STABILITY BRACKET

Fitting the Stability Bracket

(Not supplied)

If the cooker has to be installed with a
flexible supply pipe, it is necessary that a
stability device is fitted.
(See "Important Safety Requirements").

The stability bracket should be fitted by
the installer and these instructions should
be read in conjunction with the leaflet
packed with the stability bracket.

Place cooker in its intended position and
level cooker.

Mark off 295mm (11

1

/

2

") from the right

hand side of the cooker as shown, this is
the centre line of the bracket fixing.

Draw a line 100mm (4") from the front
edge of the levelling feet and remove
cooker from its position. Mark off 580mm
(23") back from this line on the centre line
of the bracket to locate the front edge of
the lower bracket.

Fix lower bracket (with two fixing holes)
to the floor, then measure height from
floor level to engagement edge on back
of cooker, dimension 'A' of figure.

Assemble upper bracket to lower bracket
so that underside of bracket is dimension
'A' +3mm (1/8") above floor level. Re-
position cooker and check that top
bracket engages into cooker back to a
depth of 75mm (3"), as shown in figure.

Should the stability bracket currently
installed not allow the cooker to stand
correctly, ask the installer to replace it with
the correct type.

Advertising