background image

Technical Data - Notes

Type of gas:

Natural Gas II

2H3+*

Please see data badge your for specified gas
type.

* Can be converted from Natural gas to LP Gas

Never attempt to convert an appliance -
unless the data badge states that you can.

Burner Aeration:

Fixed

Pressure setting:

G20 Natural Gas @ 20mbar
G30 Butane @ 28-30mbar
G31 Propane @ 37mbar

Electrical supply:

220 - 240V ~ 50Hz

Thermostat Phial location:

Front centre of oven roof.

Injectors used (hotplate)

Countries of destination:

GB

IE

Size

Natural

Gas

LP gas

Small

77

50

Medium

104

70

Large

129

87

Wok

121 & 63

87 & 35

31