Remote control, cont’d – Extron Electronics RAC 104 User Manual
Page 32

Remote Control, cont’d
RAC 104 • Remote Control
3-8
Commands can be made back-to-back with no spaces. Example 1*1!02!03*03!..
The RAC 104 supports the 2-digit numeric format (01*02).
Command
ASCII Command
Response
Additional description
(host to RAC 104)
(RAC 104 to host)
Fr
ont panel lock out (Executive modes)
Set executive mode
X6
X/x
Exe
X6
0 = of
f.
1 = mode 1 (all featur
es except volume ar
e locked).
2 = mode 2 (all featur
es ar
e locked).
V
iew executive mode status
X/x
X6
0 = of
f.
1 = mode 1.
2 = mode 2.
Information r
equests
Information request (DIP switch settings)
I/i
X1
3
V
iew DIP
switch settings (see table on page 3-4).
Request for part number
N/n
xx-xxx-xx
60-561-01.
Query software version
Q/q
X7
Tie channels together
T
ie channels together
X8
*
X3
*4#
T
ie Grp
X8
*
X3
T
ie channels in gr
oup
X8
together
(0 = not tied, 1= tied).
V
iew ties of all groups
4#
GrpA*
X3
GrpB*
X3
Gr
oup
A
tied/not tied, gr
oup B tied/not tied.