NOZZLE & NEEDLE

● Unscrew Adjustment Ring (9)

● Remove the Air Cap (8)

● Completely remove Adjustment Screw (4)

● Remove the Spring (3)

● Push out the Needle (2) – do not use tools for this

● Remove the Fluid Tip (7)

● Remove Air Flow Plate (6)

● Remove Nozzle Washer (17)

● Place all of these items into a container and clean

●

them using a brush and clean thinners

● Clean the inside of the gun

● Thoroughly dry these parts before

●

reassembling

● Grease the Fluid Needle Packing (13)

● Reassemble parts in reverse order.

●

It is recommended fitting the fluid tip (7) prior to the

●

needle

NEVER DISPOSE OF PAINTS OR SOLVENTS INTO
DRAINS. CONTACT YOUR LOCAL
COUNCIL TO ARRANGE COLLECTION OR FOR
DETAILS OF NEAREST REGISTERED DISPOSAL SITE.