background image

POWLI011

EN

Copyright © 2014 VARO

P a g e

| 2

www.varo.com

4

MOUNTING THE HALOGEN LAMP (FIG. 1)

Exclusively suited for fixed mounting.

The power is to be turned off before mounting the halogen lamp with sensor.

The fitting is to be mounted in such a way that the angle of inclination of the
longitudinal shaft of the lamp (burning position) is less than 4° with respect to the
ground area.

Secure the fitting with two screws or bolts, out of reach and at a minimum height of
2.5m.

The distance between the fitting and the object or surface to be illuminated is to be at
least 0.8m. In case you place the fitting under a canopy, a minimum distance of 0.2m,
measured from the top of the fitting to the under side of the canopy, is to be taken
into account.

Do not mount the fitting to the ceiling.

The grounding wire of the connection cable yellow/green must be connected to the
connection terminal, indicated with grounding symbol. The power wires are to be
fitted in the connection block.

In order to mount or change the halogen lamp, the power must be switched off before
opening the safety glass. After this, secure the halogen lamp into the lamp holder.
The halogen lamp is never to be touched with bare hands.

Secure the sealing rubber to guarantee the spatter resistance, and ensure that all
mounting screws are properly fastened.

Installation height of this lamp should be between 1m and 2.5m.

5

WIRING DIAGRAM (FIG. 2)

Fix the wiring in the connection block according to the included diagram (Fig. 2):
a=brown conductor of the network cable (L)
b=blue conductor power cable (N)
c=yellow/green: grounding cable
d=control (red)

6

USING THE FLOODLIGHT

Simply plug in the cable of the floodlight to the socket.

7

SETTING THE LIGHT SYSTEM (FIG. 3)

7.1 Test mode

Turn the LITE control and the Time control anticlockwise to the edge (the TEST
position).

Set the SENS. Control to its mid-point.

Turn on the wall switch. The floodlight will turn on for about 1 minute to warm up.
Then it turns off.

Walk through the detection area. The floodlight turns on when you move and turns off
when you stop. Wait for the floodlight to turn off before moving again to test the
sensor.