Extension cords, Operating instructions, Instructions before use – Powerplus POWX1770 COMPRESSOR 2200W 50L LUBRICATED EN User Manual

Page 6: Connecting and removing the air hose, Setting the operating pressure

Advertising
background image

POWX1770

EN

Copyright © 2014 VARO

P a g e

| 6

www.varo.com

 Only move the machine by lifting the handle. Never pull an attached air hose to move the

machine.

 The working parts of the machine can become hot during operation. Let the machine cool

down after use.

 The machine is equipped with a thermal safety system
 Never use gasoline or other flammable liquids to dean the too. Vapours in the tool can be

ignited by a spark and cause the tool to explode.

 If the tank leaks, switch off the machine immediately. Have the machine repaired by an

authorized technician.

 Make sure that the machine is switched off and unplugged and that the tank is pressure

free before troubleshooting or servicing, or when the machine is not used.

 After each use the tank must be vented and the moisture collected in the tank must be

bled. Not bleeding the tank can lead to leakage and may cause a dangerous situation.

 Keep this manual with your compressor.

6.1

Extension cords:

We don not recommend the use of an extension cord with this product as this may result in the
loss of power and overheating of the motor. An additional air hose should be used instead of
an extension cord. Improper use of extension cords may cause inefficient operation of tool,
which can result an overheating. Be sure your extension cord is rated to allow sufficient flow to
motor. Use of an extension cord heavy enough to carry the current the tool will draw is very
important. Especially when the power source is of great distance. An extension cord that is
insufficient will cause a drop in line voltage, resulting in not starting, power loss and causing
the motor to overheat.

7 OPERATING INSTRUCTIONS

7.1

Instructions before use.

After removing the compressor from its packaging and if you are certain that it is in perfect
condition, then you can carry out the following operations:
 Assemble the supplied wheels.
 Plastic caps at the side of the pumps, must be replaced by the supplied air filters
 You have to remove the oil cap and add oil before starting

7.2

Connecting and removing the air hose

The machine has been provided with quick couplings
for the attachment of 1 air hose.
 Press the connecting piece of the air hose into the

connection.

 Check whether the air hose is connected properly.
To remove an air hose, proceed as follows:
 Press the connecting piece of the air hose further

into the connection.

 Pull the collar on the connection backward.
 Pull out the connecting piece from the connection.
 Release the collar

Before connecting or removing an air hose, always pull the plug from the
power supply.

7.3

Setting the operating pressure

The set operating pressure can be read from the gauge.
 Turn the adjusting knob to the right to increase the operating pressure.
 Turn the adjusting knob to the left to reduce the operating pressure.

Advertising