Checking and cleaning the air filter, Trouble-shooting, Engine does not start – Powerplus POWX1770 COMPRESSOR 2200W 50L LUBRICATED EN User Manual

Page 9: Compressor does not supply air, Pressure is too high, Technical details, Noise

Advertising
background image

POWX1770

EN

Copyright © 2014 VARO

P a g e

| 9

www.varo.com

8.6

Checking and cleaning the air filter

Check the air filter every 3 months.

 Let the machine cool down.
 Pull the air filter cap from the filter.
 Clean the filter with dry air. If necessary

replace the filter.

 Pull the air filter cap back into the filter.

9 TROUBLE-SHOOTING

If the machine does not work correctly, follow the directions below to solve the problem. If you
can’t solve the problem yourself, contact your dealer.

9.1

Engine does not start

 Check that the on/off switch is in the "ON" position.
 Check that the power supply corresponds to the voltage on the rating plate of the

machine.

 Check that the fuses in the meter cupboard are intact.
 Check that no extension cords are used that do not comply with the applicable regulations.
 Check that the work environment is not too cold.

9.2

Compressor does not supply air

 Check that the pressure regulator is adjusted correctly.

9.3

Pressure is too high

 Check if the hose is connected to the correct valve.
 Re-adjust the pressure.

10 TECHNICAL DETAILS

Rated voltage

220-240 V~

Rated frequency

50 Hz

Rated Power

2200 W / 3 pk

Rotation speed

2850 min-1

Rated Pressure

9 bar / 131 PSI

Tank capacity

50 l

Air debit (capacity)

356 l/min

Weight

45 kg

Cylinder

2

Lubricated

Yes

11 NOISE

Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA

77 dB(A)

Acoustic power level LwA

97 dB(A)

ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).