Vent system identification – Empire Comfort Systems DVP48FP7 User Manual

Page 23

Advertising
background image

Page 23

17375-10-0706

Installing Vent Components (Figure 36)

Begin the vent system installation by installing the first Simpson

Duravent component, 90° elbow to the starting collars or straight

pipe on the top of the appliance, then the straight pipe length and

then horizontal or vertical termination kit.
NOTE: All outer connection joints must be sealed with aluminum

tape, screws or silicone sealant rated above 300°F/149°C. The

inner flue joints do not require any sealant.
Simpson Duravent vent system components lock into place by

sliding the concentric pipe section with four (4) equally spaced

interior beads onto the appliance collar or previously installed

component end with four (4) equally spaced indented sections.

When the internal beads of each starting outer pipe line up, rotate

pipe section clockwise 90° (approximately 3 inches). The vent pipe

is now locked together.
Continue adding components per the pre-planned vent system

configuration. Be certain that each succeeding vent component

is securely fitted and locked into the preceding component in the

vent system.

Figure 36

WALL THIMBLE

(MAXIMUM OF

THREE 90 ELBOWS)

(MAXIMUM OF

TWO 90 ELBOWS)

Special Venting Components

Simpson Dura-Vent

Can be purchased from Simpson Duravent or from

Empire Comfort Systems, Inc.

Part Number Description
SD-1208

6" Pipe Length

SD-1207

9" Pipe Length

SD-1206

12" Pipe Length

SD-1204

24" Pipe Length

SD-1203

36" Pipe Length

SD-1202

48" Pipe Length

SD-1211

Adjustable Pipe Length 11 - 14 5/8"

SD-1284

Horizontal Square Termination Cap

SD-1250

Vinyl Siding Standoff

SD-1245

45° Elbow

SD-1290

90° Elbow

SD-1249

Wall Firestop

SD-1263

Ceiling Firestop

SD-1243

Roof Flashing - 0/12 to 6/12 Roof Pitch

SD-1253

Storm Collar

SD-91291

High Wind Vertical Top

SD-1281

36" Snorkel

SD-1282

14" Firestop Snorkel

SD-1247

Wall Thimble Firestop

Special DV Vent Kits - Simpson Duravent and Empire Comfort Systems, Inc.

Can be purchased from Empire Comfort Systems, Inc.

DVVK-5R

Direct-Vent Fireplace Vent Kit for Rear Vent, 6 to 12 inch wall
thickness, Includes SD-1208, SD-1247, and SD-2184

DVVK-5T

Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 4
to 6 inch wall thickness, Includes SD-1290, SD-1284, SD-1208
and SD-1247

DVVK-5V

Direct Vent Fireplace Vent Kit - Vertical, Includes SD-1291,
SD-1253, and SD-1243

VENT SYSTEM IDENTIFICATION

Advertising
This manual is related to the following products: