CI-CW MICRO/CW EFM

Appendix D - Radio/Modem Installation Guide / D-5

Exp Comm. Module’s

MDS Transnet Radio

Connector J11

If In Slot #3

Comm. Port

Assignments

If In Slot #4

NOTE:

ECOM Module Comm. Ports

4/8 (RS-232)

are wired the same as

CPU Module Comm. Ports

4/8

6/10

1

1

1

1

4

J11

3

3

3

3

1 = 6-32 x .188” Pan Head Screw

(Qty. 4)

2 =

x .313” F/F Standoff (Nylon) (Qty. 4)

3 =

x .250” Pan Head Screw (Qty. 4)

4 = MDS Transnet Radio Cable (with Nut and Washer)

5 = MDS Transnet Radio Module

(Nylon)

6-32
6-32

MDS Transnet Radio Kit Parts

Cover Panel

EMI Gasket

MDS

Radio

module

Transnet

3

3

3

3

JP4

JP2

JP1

1

1

1

5

2

2

2

2

OPTION

Populated

by

Order

Figure D4 - MDS Transnet OEM Radio Installation Diagram