Pre-Motor Filter

Check the pre-motor filter each time the dust bag is changed.
Clean or replace as needed.

To Clean Pre-Motor Filter

1. Locate dust bag support in bottom of dust bag compartment.

Remove filter centered in the bottom of the dust bag
compartment.

2. Shake filter to remove excess dust. If necessary, the filter

can be cleaned by vacuuming with another cleaner or
washing with mild detergent.

3. Reinstall filter after completely dry.

Use GENUINE EUREKA replacement pre-motor filter, Part
No. 71480.

To remove True HEPA

cartridge

filter

1.

Push down on filter door latch and pull door away from
cleaner.

2.

Push down on HEPA cartridge latch and remove filter.

To replace True HEPA

cartridge

filter

1. Place bottom tabs of filter cartridge into slots. Rotate

filter toward cleaner, press firmly against cleaner to
latch. Make sure True HEPA cartridge latch is
secured on both sides.

2.

Replace filter door by placing tabs of door into slots on
cleaner. Rotate door up and against cleaner until it locks
into place.

NOTE: To have the benefit of a sealed True HEPA

system, you must use one of the True HEPA
cartridge filter systems.

To remove Filter Pad from

filter door

1.

Push down on filter door latch and pull door away from
cleaner.

2. Lift filter pad up and out of filter door. Dispose of old filter

pad.

To replace Filter Pad into

filter door

1.

Place new filter pad in filter door.

2.

Replace filter door by placing tabs of door into slots on
cleaner. Rotate door up and against cleaner until it locks
into place.

Filter Pad Replacement Options:
HEPA, Style HF6

Models equipped with Cartridge Filter

(Only cartridge style filters can be used with these
models.)
Check the True HEPA filter each time the dust bag is
replaced. Replace filter cartridge twice a year or as needed.

Models equipped with Filter Pads

Check the filter pad each time the dust cup is
emptied. Replace twice a year or as needed.

Filter
Door
Latch

Use GENUINE EUREKA replacement True HEPA filter,
Style HF5.

Use GENUINE EUREKA replacement filter pads.

True HEPA
Cartridge
Latch

Filter
Door
Latch

F i l t e r
Pad

Pre-Motor
Filter

Dust Bag
Support

Side Door Filt

ers

R

OUTINE MAINTENANCE