Hearth mount installation, Installation – Enviro 50-1574 User Manual

Page 16

Advertising
background image

H

EARTH

M

OUNT

I

NSTALLATION

:

EF 5

Existing Fireplace

Clean Out Tee

Fireplace Damper

Location

Rain Cap

Seal Plate

Vent Pipe (single

wall stainless flex

pipe or PL vent)

Existing Masonary

Flue

Flexible Vent Connector

(Use this 5 ft section of

pipe to vent past

fireplace damper or

smoke shelf)

Installation

Rain cap

Flashing

24"

(61 cm)

4"

(10cm)

Tee with

cleanout

Fresh air

intake

3" (7.5 cm)

Clearance

Support

bracket

Type "L"

vent

Figure 15: Outside Vertical Installation.

Figure 16: Hearth mount installation.

Refer to Figures 16.

1. Lock fireplace damper in the open position.

2. Install a positive flue connector at the

fireplace dampers.

3. Connect a tee or a 90° elbow to the exhaust

pipe.

4. Install flexible stainless steel liner or listed

pellet vent to the top of the chimney.

16

Advertising