Al113kcl-300123-e-p10, Richland – Kichler 300123 User Manual

Page 11

Advertising
background image

10

14. SPECIFICATIONS

1.50'

24.20

kgs

26.40

kgs

0.35

0.26

0.17

42.0

23.0

9.0

213

156

94

3215.79

2447.58

1364.18

RPM

CFM

76.57

106.42

151.58

CFM/W

N.W. G.W. C.F.

120

120

120

Fan Size

42"

Speed Volts Amps Watts

High

Medium

Low

These are approximate measures. They do not include Amps and Wattage used by the light kit.

13. TROUBLESHOOTING

Problem

Fan will not start.

Fan sounds noisy.

Fan wobble.

Solution

1. Check that all fuses or circuit breakers are installed or in the ON position.
2. Check all electrical connections to insure proper contact.

CAUTION: Make

sure the main power is OFF when checking any electrical connection.

1. Make sure all motor housing screws are snug.
2. Make sure the screws that attach the fan blade bracket to the motor hub is

tight.

3. Make sure wire nut connections are not rubbing against each other or the

interior wall of the switch housing.

CAUTION: Make sure main power is off.
4. Allow a 24-hour "breaking-in" period. Most noise associated with a new fan

disappear during this time.

5. If using an optional light kit, make sure the screws securing the glassware are

tight. Make sure the light bulbs are not touching any other component.

6. Some fan motors are sensitive to signals from solid-state variable speed

controls. If you have installed this type of control, choose and install another
type of control.

7. Make sure the upper canopy is a short distance from the ceiling. It should not

touch the ceiling.

1. Check that all blade and blade arm screws are secure.
2. Most fan wobbling problems are caused when blade levels are unequal. Check

this level by selecting a point on the ceiling above the tip of one of the blades.
Measure this distance. Rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. The distance deviation should be equal
within 1/8".

3. Use the enclosed Blade Balancing Kit if the blade wobble is still noticeable.
4. If the blade wobble is still noticeable, interchanging two adjacent (side by side)

blades can redistribute the weight and possibly result in smoother operation.

WARNING:

TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE BLADE

ARMS WHILE INSTALLING, BALANCING OR CLEANING THE FAN. DO NOT INSERT
FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES.