Installation – Enviro 50-1095 User Manual

Page 16

Advertising
background image

Installation

T

YPICAL

T

HROUGH

W

ALL

W

ITH

E

XTERIOR

B

LOWER

K

IT

I

NSTALLATION

- H

ORIZONTAL

T

ERMINATION

:

Electrical Cable

Bern

90° Elbow

45°Elbow with Rodent

screen or stainless

steel termination hood

2ft (610mm) Riser

Pipe Adaptor

Exterior Blower

and Housing

Wall Strap

To supply power to

the exhaust blower

Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble plate

and attach to the pre drilled hole in the left hand rear hopper pillar. Hook up to wires from the exhaust

blower wiring harness.
All electrical connections must be in accordance to local code requirements

NOTE:

Ensure that all interior vent connections are sealed by placing a small bead of high temperature silicone

around each chimney connection.

Also ensure that all vertical vent sections are properly supported and that all clearances to combustibles

are maintained in accordance with the vent manufacturer’s specifications.

Figure 19: Through Wall Installation with Exterior Blower Kit.

Figure 20: Through Wall Installation with Exterior Blower Kit; Side View.

16