Installation – Enviro 50-1095 User Manual

Page 7

Advertising
background image

7

Installation

C

LEARANCES

TO

C

OMBUSTIBLES

:

Use a hearth pad that extends 6 inches (15 cm) in front of the unit when installing on a combustible

floor.

A

LCOVE

C

LEARANCES

:

This unit may be installed in an alcove. Maintain

these clearances to combustibles.

Minimum Alcove width

48 inches (122 cm)

Minimum Alcove height

48 inches (122 cm)

Maximum Alcove depth

48 inches (122 cm)

Install vent at clearances specified by

the vent manufacturer.

S

id

e

W

al

l

Back Wall

Adja

cen

t W

all

8"

(20cm)

4"

(8cm)

4" (8cm)

���

�������

���

�������

���

�������

These dimensions are minimum clearances but it

is recommended that you ensure sufficient room

for servicing, routine cleaning and maintenance.

Side wall to unit 8 inches (20 cm)

Back wall to unit 4 inches (10 cm)

Corner to unit

4 inches (10 cm)

Figure 3: Bern Clearance to Combustibles.

Figure 4: Bern Minimum Alcove Size.

Advertising
This manual is related to the following products: