Crivit 1-LD3141 User Manual

Page 4

Advertising
background image



- 16 -

Notes on the BMI
The BMI is a statistical measurement that can be used to judge a
persons weight. For adults, a value between 18.5 and 25 is considered
normal. Values below 18.5 are considered "underweight". Values above
25 are considered "overweight". Values above 30 are considered
"Obese".
The BMI is only a coarse guideline because it does not take a persons
body type and body composition into consideration.

Fitness

FITNESS

LEVEL

FITNESS

LEVEL

NIV FORM

PHYSIQ

NIVEL

FIT

After your training, immediately press SET. A 5 minute countdown will
start (cool down phase).
The bar will show the remaining time. On the left side of the display the
heart rate at the beginning of cool down is shown. On the right side of
the display the current heart rate is shown. The countdown time is
shown on the bottom row of the display.
After 5 minutes your fitness level will appear.

Fitness level

Heart rate

6

>130

5

130-120

4

120-110

3

110-105

2

105-100

1

<100



- 17 -

Coded transmission

The chest belt's transmissions are digitally coded to prevent
interference if you are training with a training partner who is using an
identical watch and chest belt.
When using the chest belt for the first time, a random channel is
selected automatically. The channel is briefly displayed at the top of the
display upon entering the heart rate display mode. The available
channels are CH10, CH11, CH12, CH13 and CH14.
The channel can be changed by briefly removing the battery from the
chest best and reinserting it. The chest belt will randomly select a
channel and after approx. 1 minute the heart rate and the new channel
will appear on the display of the watch.

Troubleshooting

The heart rate is not shown or is shown incorrectly
Make sure the chest belt is positioned correctly and fits well.
Your skin should not be too dry or too cold.
The contact areas can be slightly moistened to improve function.
Electromagnetic interference may have an adverse effect on reception.
The distance between watch and chest belt must be under 70cm.
Other heart rate measuring devices within a 2m range may also cause
interference.
Wireless bicycle computers may cause interference.
The batteries may be low and require replacing.

The display is unreadable / the light does not work
Replace the batteries.



- 18 -

Disposal

Disposal of the electronic appliance
This electronic appliance may not be disposed of with normal
household waste. Dispose of the unit at an approved disposal
facility or at your local recycling centre. Please observe the
current rules and regulations when disposing of the appliance.
Contact the disposal system if in doubt.


Disposal of the batteries
Please dispose of your batteries properly in containers especially
set up at retailers. Batteries do not belong in household waste.
Dispose of the batteries at an approved disposal facility or at your
local recycling centre. Contact the disposal system if in doubt.

Replacement of battery

Battery replacements should be performed by an expert to avoid
damaging the case or gaskets.

Battery low indicator

If the battery voltage on the chest belt battery drops below the voltage
required for normal operation,

TXBELT

LO BAT

TXGURT

BATT

SNGLTX

PILE

TXBCIN

BAT BA

will appear on the display. Replace the battery of the chest belt as
described in the chapter "Chest belt".



- 19 -

Warranty

We provide a 3-year warranty for this item. The warranty period starts
from the date of sale (receipt, proof of purchase). Within this period we
rectify all faults which are attributable to material and manufacturing
defects at no cost. For damage which is caused by improper treatment,
e.g. dropping, knocking, or water damage, there is no warranty claim.

Declaration of conformity

If used as intended this product conforms to the basic standards of § 3
and the other relevant provisions of the FTEG (Section 3 of the R&TTE
directive).
You can request the declaration of conformity here:
[email protected]

Water resistance

Water resistant up to 3 bar. The bar value specifies the atmospheric
overpressure which is applied during testing (DIN 8310).



- 20 -

Water resistance of the chest belt

Water resistance according to IEC 60529 IPx7: 30m

Technical specifications


Wrist watch

Operating temperature

0-50°C

Dimensions

4,4 x 5,0 cm

Display

2,4 x 1,8 cm

Weight

51 g


Chest belt

Operating temperature

0-50°C

Dimensions

7 x 3,3 x 1,2 cm

Frequency

110 kHz

Weight

51 g



- 21 -



Pulsur med brystsele

Forord

Før dette apparat bruges første gang, bedes De venligst læse de
pågældende instruktioner i denne håndbog, også selvom De er godt
kendt med omgangen af elektroniske apparater. Vær især opmærksom
på kapitel "Vigtige sikkerhedshenvisninger". Opbevar denne håndbog
omhyggeligt som fremtidig reference. Hvis De sælger dette apparat
eller giver det videre, bør De absolut overlevere denne brugsanvisning.

Vigtige sikkerhedshenvisninger

GIV AGT: Tal med Deres læge før De begynder
med træningen. Han kan oplyse Dem om den
træning, der er bedst velegnet for Dem, om
træningsintensiteten og om pulsmålsætningen.
Dette pulsmåler-armbåndsur er ikke et medicinsk
apparat og gælder kun som understøttelse af
Deres træningsformgivning.


Renholdelseshenvisninger
Gør apparatet kun rent med en tør, fnugfri klud, som f.eks. anvendes til
rengøring af briller.

Advertising