GB MT

Check this by placing the pump

into a vessel filled with water

and lift the float switch (6) care-

fully by hand and then lower it

again. In this case, you can see

whether the pump switches on

and off.

- Also ensure that the separa-

tion distance between the float

switch (6) head and the float

switch height adjustment (5) is

not too small. In the case of a

separation distance which is too

small, trouble-free functioning

cannot be guaranteed.

- During the adjustment of the

float switch (6), ensure that the

float switch does not contact the

floor before the pump switches

off.

The pump run dry if too long a

float switch cable (

3) is chosen,

particularly if the float switch height

adjustment (

5) is not installed

(see „Operational start-up“).

Manual mode / flat suction

In manual mode, the pump does not

switch off automatically, as the float

switch is bypassed.

Position the float switch (6) verti-

cally upward in the float switch

height adjustment (5).

Monitor the pump constantly when

in manual mode. Switch the pump

off immediately (disconnect from

the mains) if no more water is

being pumped. There is a risk of

damage if the pump runs dry.

Maintenance and Cleaning

Clean and maintain your equipment regu-

larly. This will guarantee its performance

and long durability.

Ask our service centre to carry

out any work that is not de-

scribed in these instructions.

Use only original parts. There is

a risk of injury!

Pull out the power plug before eve-

ry maintenance operation. There

is a risk of electrocution or of injury

from moving parts.

General cleaning instructions

• In case of transport for utilization in

different locations, the pump must be

cleaned with clear water after every

use.

• In case of stationary installation, the

function of the float switch (

6) is

to be checked regularly (at the latest

every three months).

• With a water jet, remove fluff and

fibrous particles which are possibly

present in the pump casing (

12).

• Clean precipitation from the float

switch (

6) with clear water.

• Regularly remove sludge from the pit

base (at the latest every 3 months)

and also clean the shaft walls

• In the case of a long period of non-

use, the pump must be thoroughly

cleaned after the last use and before

the new use, since difficulties in start-

up can arise due to precipitation and

residues.