GB

earthing; the residual current circuit

breaking must be compliant with

the safety regulations of the energy

supply company and function with-

out fault,

- The protection of the electrical plug

connections from the wet.

- If there is a risk of flooding, fix the

plug connections in an area that is

safe from flooding.

• Ensure that the mains voltage matches

the specifications on the rating plate.

• The electrical installation shall be ac-

cording to national wiring rules.

• Connect the appliance to a power

socket with a residual current circuit

breaker of rated residual current no

more than 30 mA; minimum fuse 6 am-

peres.

• Before each use, check the equipment,

cable and plug for damage. Defec-

tive cables are not to be repaired, but

rather replaced by new ones. Have

damage on your equipment repaired

by an authorised specialist.

• If the power cable for this equipment is

damaged, it must be replaced by the

manufacturer, a customer service agent

of the same or a similarly qualified per-

son in order to prevent hazards. The

line must be minimum 10 m long.

• Do not pull the plug from the socket by

the cable. Protect the cable from heat,

oil and sharp edges.

• Do not carry or fix the equipment by

the cable.

• Use only extension cables that are pro-

tected from spray water and designed

for outdoor use. Always fully unroll

a cable drum before use. Check the

cable for damage. The flexible lead

cross-section of the extension cord must

at least 2.5 mm

2

.

• Disconnect the mains plug from the

socket before all work on the equip-

ment, in case of leaks in the water

system, during work breaks, and when

not in use.

Initial Operation

Positioning/Hanging

• The dimensions of the pump shaft must

be not less than 40 x 40 x 50 cm, in

order that the float switch (

7) can

move freely.

• The pump can be suspended by the

round handle (

1) or placed on the

shaft floor.

The pump can be suspended and/or

removed using the nylon cord (

11)

provided.

To hang up safely, loop the nylon cord

around both of the cable holders that

are pointing downwards and pull it up-

wards through the round handle.

Never suspend the pump by the hose.

Ensure that the equipment is

not hung up or held by the

mains cable. There is a risk

of electric shock from dam-

aged mains cables.

Note that, over time, dirt and sand

may collect on the bottom of the

shaft, which could damage the

pump.

We recommend standing the pump

on a brick.

If the water level is too low, the silt

in the shaft can quickly dry out and

impede the pump when warming

up.

Advertising