Troubleshooting, Replacement parts/accessories – Florabest FTS 1100 B2 User Manual

Page 47

Advertising
background image

47

GB

Troubleshooting

Faults

Causes

Remedies

Pump does not start

Mains voltage is not applied

Check mains voltage

Float switch (

7) does not

switch

Bring float switch into higher

position

Pumps has no dis-

charge

Buckled pressure hose

Repair point at which the line

is bent

Trapped air in the pump cas-

ing

Tip the pump underwater until

the air escapes

Pump does not switch

off

Float switch (

7) cannot

drop

Set up pumps correctly on the

pit base

Flow rate insufficient

Reduces pump performance,

through severely contami-

nated water and additions in

the water which produce a

grinding effect

Clean pumps and replace

wear parts

Pump switches off after

a short period

Motor contactor disconnects

the pumps because of water

pollution that is too severe.

Pull out power plug and clean

the pump as well as shaft

Water temperature too high,

motor contactor breaks

Note maximum water tem-

perature of 35 °C!

Replacement parts/Accessories

You can order replacement parts and accessories directly via our Service Centre (see

page 46). Ensure that you include the order number when placing the order.

Item

Description

Product No.

4 Floor plate + screw set (

4a) 91100892

9/10

Connector set (reducer, sealing ring, angle adapter)

91100893

11

8m nylon cord

91100894