GB

Working

Supervise the appliance while it is

in operation in order to be immedi-

ately aware if the automatic cut-out

operates or the pump runs dry, to

limit any damage to a minimum.

In automatic mode, the float switch auto-

matically switches the pump on or off.

Adjusting the float switch:

The on/off switch point on the float switch

(

6) can be adjusted by changing the

position of the float switch in the float

switch grid (

8).

In the case of stationary installation,

check regularly (no less then once

every three months) that the float

switch (

6

) is working.

Check the float switch (

6):

- It must be positioned so that it

can lift and lower freely. The

switching point heights “On”

and “Off” must be easy to

reach.

Check this by placing the pump

into a vessel filled with water

and lift the float switch (6) care-

fully by hand and then lower it

again. In this case, you can see

whether the pump switches on

and off.

- Ensure that the distance between

the float switch and the float switch

grid (

8) is not too small.

- During the adjustment of the float

switch (6), ensure that the float

switch does not contact the floor

before the pump switches off.

The pump will run dry if too long a

float switch cable (

7) is chosen.

Maintenance and

Cleaning

Clean and maintain your equipment regu-

larly. This will guarantee its performance

and long durability.

Ask our service centre to car-

ry out any work that is not

described in these instruc-

tions. Use only original parts.

There is a risk of injury!

Pull out the power plug before eve-

ry maintenance operation. There is

a risk of electrocution or of injury

from moving parts.

General cleaning instructions

• In case of transport for utilization in

different locations, the pump must be

cleaned with clear water after every use.

• In case of stationary installation, the

function of the float switch (

6) is

to be checked regularly (at the latest

every three months).

• With a water jet, remove fluff and

fibrous particles which are possibly

present in the pump casing (

3).

• Clean precipitation from the float

switch (

6) with clear water.

• Regularly remove sludge from the pit

base (at the latest every 3 months) and

also clean the shaft walls

Advertising