background image

4

CONFIGURATION

The configuration menu allows you to set thermostat operating characteristics to your system or personal requirements.

To enter the menu, press TIME

FWD

and TIME

BACK

once at the same time. Press TIME

FWD

to advance through the

menu options. Press arrow keys to change options.

1

Step

Press Button(s)

Displayed

Press or to select:

COMMENTS

Ref

(Factory Default)

Page

0 F

(0)

5 LO to

5 HI

Adjusts temperature display higher or lower.

2

EMR
(ON)

OFF ON

ON L

Selects EMR option ON or OFF or ON L.

TIME

FWD

TIME

FWD

3

RH

(0)

20 LO to

20 HI

Adjusts humidity display.

TIME

FWD

4

DRY

(OFF)

LO or HI to OFF

To reduce or eliminate condensation during cold
weather. Use LO setting first, if condensation persists
use HI setting.

TIME

FWD

5

OPTM CMFT

(ON)

OFF

Enables improved dehumidification in cooling mode
if humidity is above setting.

TIME

FWD

6

OPTM DHUM

(OFF)

ON

Available if OPTM CMFT is ON. Provides extra
dehumidification if humidity is above setting. May
reduce temperature setpoint by up to 3 degrees.

TIME

FWD

User Configuration Menu

6

6

7

7

7

8