Sealey SA316 User Manual

Sa316.v2, Air/hydraulic riveter heavy-duty vacuum system, Safety instructions for

Advertising
background image

4.1.

Air Supply

WARNING! Ensure the air supply is clean and does not exceed 90psi while operating the riveter. Too high an air

pressure and unclean air will cause excessive wear, and may be dangerous, causing damage and/or personal injury.

Recommended hook-up procedure is shown in Fig.1.

4.1.1. Ensure the riveter air valve (or trigger) is not depressed before connecting to the air supply.

4.1.2. You will require an air pressure between 70-90psi, and an air flow according to the specification above.

4.1.3. Drain the air tank daily. Water in the air line will damage the riveter and invalidate your warranty.

4.1.4. Clean air inlet filter weekly.

4.1.5. Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The minimum hose diameter should

be 1/4” I.D. and fittings must have the same inside dimensions.

4.1.6. Keep hose away from heat, oil and sharp edges. Check hoses for wear, and make certain that all connections are secure.
4.2. Couplings

Vibration may cause failure if a quick change coupling is connected directly to the riveter. To overcome this, connect a leader hose

Sealey model number AH2R or AH2R/38 - to the riveter. A quick change coupling may then be used to connect the leader hose to the

air line recoil hose. See figs.1 & 2.

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions

and properly maintained, give you years of trouble free performance.

1. SAFETY

INSTRUCTIONS FOR:

AIR/HYDRAULIC RIVETER HEAVY-DUTY

VACUUM

SYSTEM

MODEL No:

SA316.V2

Powerful, extra heavy-duty tool suitable for aluminium, steel, stainless steel rivets and structural rivets from 3/16” to 1/4”. Trigger operated

riveter with hardened steel jaw assembly and air-actuated vacuum rivet shaft collector. Resilient grip for added comfort and hanging loop for

use with balancer. Supplied with three riveting nozzles, two spanners and oil can.

Nozzle Sizes: . . . . . . . . . . . 3/16”(4.8mm), 7/32”(5.6mm)1/4”(6.4mm)

Air Consumption: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4cfm

Operating Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90psi

Air Inlet Size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BSP

Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.9kg

Noise Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84.8dB(A)

Noise Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73.8dB(A)

Vibration Figure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.44m/s²

4. AIR SUPPLY

WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.

Familiarise yourself with this product’s application and limitations, as well as the potential hazards peculiar to the riveter.

WARNING! Disconnect the riveter from the air supply before changing accessories, servicing or performing any maintenance.

Maintain the

riveter in good condition (use an authorised service agent).

Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

Use in a suitable work area. Keep area free from unrelated materials and ensure that there is adequate lighting.

Keep the riveter clean for best and safest performance.

WARNING! Always wear approved eye (or face) and hand protection when operating the riveter.

Maintain correct balance and footing. Do not over reach, ensure the floor is not slippery, wear non-slip shoes.

Remove ill fitting clothing. Remove ties, watches, rings, loose jewellery. Contain or tie back long hair.

Wear appropriate protective clothing and keep hands and body clear of working parts.

Keep the riveter away from your body and at a safe distance from others.

Keep children and unauthorised persons away from the working area.

Secure non stable workpieces with a clamp, vice or other adequate holding device.

Ensure that spent rivet stems are disposed of correctly and do not cause a hazard.

WARNING! Ensure correct air pressure is maintained and not exceeded. Recommended pressure:85-90psi.

Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use, and ensure that all connections are secure.

Avoid unintentional starting.

DO NOT use the riveter for a task it is not designed to perform.

DO NOT operate the riveter if any parts are damaged or missing as this may cause failure and/or personal injury.

DO NOT carry by the hose, or pull the hose from the air supply.

DO NOT get the riveter wet or use in damp or wet locations or areas where there is condensation.

DO NOT allow untrained persons to operate the riveter.

DO NOT operate the riveter when you are tired or under the influence of alcohol, drugs or intoxicating medication.

DO NOT direct air from the air hose at yourself or others.

When not in use, disconnect from the air supply and store in a safe, dry, childproof location.

Original Language Version

SA316.V2 Issue3(L) - 12/02/15

© Jack Sealey Limited

Refer to

Instructions

Wear Eye

Protection

2. INTRODUCTION

3. SPECIFICATIONS

Advertising