6. TROUBLESHOOTING

email

Sole UK Distributor, Sealey Group,

Kempston Way,

Suffolk Business Park,

Bury St. Edmunds, Suffolk, IP32 7AR

Environmental Protection.

Recycle unwanted materials instead of disposing of them as waste.

All tools, accessories and packaging should be sorted, taken to a recycle centre

and disposed of in a manner which is compatible with the environment.

THE PROBLEM

THE CAUSE

THE SOLUTION

Paint Runs.

Too much paint applied

Press trigger lightly

Air brush too close to object

Hold further away from object.

Moving air brush too slowly along workpiece Move at a faster speed.

Grainy Spray.

Paint too thick.

Thin paint.

Dried deposits on tip, needle or regulator.

Clean air brush thoroughly.

Paint Splattering.

Needle snapping back into tip.

Release needle gently.

Paint

too

thick

Thin

paint.

Curved Stroke.

Air brush arcing too close to object.

Keep air brush parallel to the object,

unless

curved

stroke

is

desired.

Paint Spitting.

Needle snapping back into tip.

Release needle gently.

Paint

too

thick.

Thin

paint.

Restricted Spray.

Air adjusting valve out too far.

Loosen the air adjusting valve to obtain the

correct

spray.

Paint tube in pot clogged.

Clean as described above.

Bubbles in Paint Cup. Air adjusting valve out too far.

Adjust air valve to eliminate bubbles.

Paint tube in pot clogged.

Clean as described above.

Erratic Spray.

Fluid needle bent or paint deposits on needle. Replace needle or clean as required.

01

04

07

03

05

02

Fig. 4

Nozzle seat

(internal)

06 "wrench" not shown

Item Part number

Description

01 AB931.V2-01

Gun module complete

02 AB931.V2-02

Air regulator valve

03 AB931.V2-03

Gravity cup

04 AB931.V2-04

Fluid adjustment screw

05 AB931.V2-05

Hose assembly

06 AB931.V2-06

Wrench (not shown)

07 AB931.V2-07

Adaptor, air hose

AB931.V2 Issue: 1 10/01/14