Sealey AUTOCHARGE124 User Manual

Page 3

Advertising
background image

3.2. BATTERY CHARGING:

WARNING! Ensure you read, understand and follow all safety instructions in Section 1 before attempting to use the

AUTOCHARGE124.

WARNING! It is advised before charging, to disconnect and remove the battery from the vehicle to prevent damage

to sensitive onboard equipment. Remember to provide a back-up supply for onboard electronics and to retain any

security codes. Check Sealey Model No. VS207 for this function.

NOTE: FOR A VERY FLAT BATTERY, DISCONNECT CABLES FROM BATTERY TERMINALS AND ALLOW BATTERY TO REST FOR 30 MINUTES

BEFORE ATTEMPTING TO CHARGE.

3.2.1. AUTOCHARGE124 can be used to charge 12V and 24V batteries. Before connecting to the battery or to the mains supply,

check the voltage of the battery and set the voltage selection switch to the appropriate value.

3.2.2. If the battery is not a sealed unit, remove the filler caps and check the level of the electrolyte. If it is below the recommended

level, top up using distilled water.

DO NOT use tap water under any circumstances. To prevent acid splashing during the

charging proccess, replace the filler caps but do not tighten them, allowing gases to escape.

3.2.3. If sealed unit, it is uneccassary to carry out the checks outlined in 3.2.2.

3.2.4. Connect power clamps to the battery terminals, ensuring correct polarity.

3.2.5. Plug the charger into the mains power supply. The charge status LED should now be illuminated red and the ammeter needle over to

the right.

3.2.6. When the charge status LED turns to green the battery is fully charged and the ammeter needle should be over to the left.

3.2.7. Unplug the unit from the mains before removing the clamps from the battery.

3.2.8. Carefully wipe any spillage of acid from the battery top and replace battery caps, if removed.

3.2.9. For long term maintenance of batteries on irregularly or seasonally used vehicles the charger can be connected to a battery for an

indefinite period - the intelligent circuitry constantly monitoring the voltage and maintaining the charge level at optimum.

NOTE: If left on charge this way, you must check the battery's electrolyte level at regular intervals.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

AUTOCHARGE124 Issue: 1 - 27/06/11

Advertising