9. GENERAL TROUbLESHOOTING

01284 757500

01284 703534

[email protected]

Sole UK Distributor

Sealey Group,

Bury St. Edmunds, Suffolk.

www.sealey.co.uk

Web

email

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.

PRObLEM

POSSIbLE CAUSES

REMEDY

NO OUTPUT FROM PUMP

Not fully primed

Open priming port and fill chamber with water

Inlet pipe leakage

Tighten clamp and/or renew pipe

Pump speed too slow

Investigate cause / increase speed if required

Filter basket is clogged

Remove obstruction / debris

Suction / overall head too high

Reduce instalation height to recommended levels

Damaged pump seal causing air leak

Return to Sealey dealer to install new seals

INSUFFICIENT FLOW OF

WATER

Filter basket, impeller or pipeline obstructed

Inspect and clear obstruction

Speed is too slow

Increase speed

Impeller seal badly worn

Return to Sealey dealer for adjustment or replacement

Inlet pipe leakage

Tighten clamp and/or renew pipe

Damaged impeller

Return to Sealey dealer for replacement

EXCESSIVE FUEL

CONSUMPTION

Impeller rubbing on casing

Return to Sealey dealer for adjustment

Impeller obstructed by weeds or foreign matter Clear obstruction

FLOW CEASES SUDDENLY

Inlet connector loose and leaking

Tighten connector locking ring

Cavitation caused by too high a suction head

Lower the position of the pump

UNIT NOISY & VIBRATING

Cavitation caused by too high a suction head

Lower the position of the pump

Excessive water output

Decrease speed to reduce output

Input pipe obstructed by foreign body

Inspect and clear obstruction

Loose rotary part

Return to Sealey dealer for identification and replacement

Unstable pump instalation

Stop engine and consolidate position of unit

Air in the pump or pipeline

Stop engine, open priming port to release air

Impeller damaged

Return to Sealey dealer for replacement

© Jack Sealey Limited