2-Wire/4-Wire = 4 Wire

TX Level = (as required; use -15 dBm if line loss is 0 dB)

Dial Backup = Manual

Loop Back Time = 15 minutes

Dial Line = RJ11

Line Current Disconnect = Long

Long Space Disconnect = Enabled

V.22 Guard Tone = Disabled

MNP Options

MNP Protocol = Enabled

Auto Fallback = Enabled (or Normal)

Flow Control = CTS Only

XON/XOFF Pass Through = Enabled

Data Compression = Disabled

Inactivity Timer = Off

Break Control = 5

DTE Options

Synchronous/Asynchronous Data = Asynchronous

DTE Rate = 9600

Character Length = 8 Bits

Parity = None

Commanded Dialer = Asynchronous

AT Command Set = Disabled

DTR Control = Disabled

DSR = Forced High

DCD = Normal

CTS = Forced High

DTE Fallback = Disabled

Options = Retained At Disconnect

Test Options - All Disabled (or factory defaults)

Dial Line Options - (not applicable; leave at factory
defaults)

Speaker Options

Volume Control = Low

Control = On Until Carrier Detect

Audio Links

Audio Concentrator Cards at the back of the CEC/IMC

cabinet provide audio connections at the CEC/IMC. Like the
control data connections, audio connections are normally
extended out of the CEC/IMC cabinet via Telco cable(s) and
line terminations are actually made at punch blocks. See
Figure 6A. See the customer-specific system documentation
print-outs for Concentrator Card connector pin-out details.

Table 5 shows line requirements between the C3

Maestro and the CEC/IMC for each audio input or output 2-
wire 600-ohm twisted pair. Note that two (2) Enhanced
Audio Enclosure output pairs, Line 2 out and Line 3 out are
never used. These audio output lines are provided for future
expansion use.

At the C3 Maestro, audio connections terminate at the

DB-25 connector on the Enhanced Audio Enclosure's rear
panel. This connector is labeled "

LINES 1-4

". Its pin-out is

shown in Figures 5 and 6A and Table 12. It has female
contacts; therefore, the required mating connector is a male
DB-25.

Normally, a pre-wired 100-foot (30.5 meters) cable is

supplied with the console equipment package for audio
interconnections between the Enhanced Audio Enclosure
and the CEC/IMC. This 8-pair shielded cable's part number
is 19B804083P2. It has a male DB-25 connector on one end
for mating to the Enhanced Audio Enclosure's "

LINES 1-4

"

female DB-25 connector. The other end is "pig-tailed" (not
terminated) so the cable's 24-guage solid wires can be
punched down to the correct terminals at the required
CEC/IMC's punch block.

G

If cable 19B804083P2 is used, mate its DB-25 to
the Enhanced Audio Enclosure, route it to the
CEC/IMC, shorten it as required, and punch the
wires to the correct punch block's terminals. Wire
color coding is indicated in Figure 5 and in the
cable's assembly diagram shown at the end of this
manual (page 37). Refer to the CEC/IMC
customer-specific system documentation print-outs
for CEC/IMC Audio Concentrator Card pin-outs
which map over to the punch blocks via Telco
cables.

Advertising