Electrolux D1100-4 User Manual
Page 33
 
33
CONNECTING TO THE MAINS TERMINAL
 
 
Warning: This appliance must be earthed.
•
We recommend you use a new length of 6mm
2
twin core and earthed cable to ensure your 
safety. 
•
Make connection as shown in Fig. 7 by 
proceeding as follows:- 
•
Preform wires to the appropriate shape to suit 
fitting into the mains terminal block. 
•
Strip inner insulation on wires using 
wirestrippers. 
•
Twist the bared wires using pliers.
•
Cut bared wires 10mm away from the end of the 
inner insulation. Where uninsulated Earth wires 
are used ensure they are suitably sheathed to 
leave 10mm bare wire to fit into the terminal. 
•
Clamp bare wires into the relevant terminal and 
check they are held by tugging each one in turn. 
•
Clamp the mains cable securely ensuring 5mm of 
the outer insulation is inside the terminal block 
and that the wires are not taught but not so slack 
as to cause any fouling. See Fig. 7. 
•
Place fuse/miniature circuit breaker in circuit and 
switch on at mains. 
CHECKING ELECTRICAL CONNECTIONS
Correct electrical connection can be confirmed when 
switching on the appliance as the timer will be 
flashing. 
NOTE: HOUSE CIRCUIT
Earth leakage and continuity tests must be carried 
out before the appliance is connected to the mains 
supply and re-checked after fitting. 
CONNECTING TO A HOB OR COOKER 
POINT 
•
Either follow in general terms the instructions for 
connecting to the terminal block or refer to the 
hob suppliers installation instructions. 
 
 
Feed the cable through the cabinet and 
arrange to route the cable away from the 
appliance which may become hot. 
 
 
Fig.7